1 |
Exhaust filter |
2 |
Ozone filter |
Pull out the exhaust filter.
Unpack the new exhaust filter.
Insert the new filter.
Pull out the ozone filter.
Unpack the new ozone filter.
Insert the new filter.
1 |
Pick roller |
2 |
Feed roller |
3 |
Separator roller |
Turn off the printer.
Remove all trays.
Standard tray
Optional 2 x 500- or 2500-sheet tray
Open door C. Make sure that it does not hit any cable attached to the printer.
Open door D.
Notes:
Locate the rollers.
Remove the rollers.
Insert the new rollers until they click into place.
Close doors C and D.
Insert the trays.
Turn off the printer.
Open door C. Make sure that it does not hit any cable attached to the printer.
Remove the door stopper.
Loosen the screws of the transfer module lock.
Remove the paper guide.
Lift the transfer module using the handles, and then pull it out completely.
Unpack the new transfer module.
Insert the new transfer module until it clicks into place.
Place the paper guide back into place.
Tighten the screws of the transfer module lock.
Reinstall the door stopper.
Close door C.
Open door C. Make sure that it does not hit any cable attached to the printer.
Pull out the transfer roller.
Unpack the new transfer roller.
Insert the new transfer roller until it clicks into place.
Close door C.
Turn off the printer.
From the control panel, hold down 2 and 6 while turning the printer on. Release the buttons when the screen with the progress bar appears.
From the Configuration menu, navigate to:
Reset Maintenance Counter > Reset 300K Maintenance Kit
Touch Back , and then exit the Configuration menu.