Leave enough room to open trays, covers, and doors and to install hardware options.
Set up the printer near an electrical outlet.
Make sure that airflow in the room meets the latest revision of the ASHRAE 62 standard or the CEN Technical Committee 156 standard.
Provide a flat, sturdy, and stable surface.
Keep the printer:
Clean, dry, and free of dust
Away from stray staples and paper clips
Away from the direct airflow of air conditioners, heaters, or ventilators
Free from direct sunlight and humidity extremes
Observe the recommended temperatures and avoid fluctuations.
Ambient temperature |
10 to 32.2°C (50 to 90°F) |
Storage temperature |
-40 to 43.3°C (-40 to 110°F) |
Allow the following recommended amount of space around the printer for proper ventilation:
1 |
Top |
120 mm (5 in.) |
2 |
Rear |
260 mm (10 in.) |
3 |
Right side |
120 mm (5 in.) |
4 |
Front |
550 mm (22 in.)
Note: The minimum space needed in front of the printer is 76 mm (3 in.). |
5 |
Left side |
120 mm (5 in.) |