Some scan settings do not work well in combination, and results will vary. While others may exist, the following combinations are known to be incompatible:
Scan setting | Does not work with |
---|---|
compression= NONE |
|
compression = JPEG | TYPE = TIFF |
compression = ZLIB |
|
compression = PACKBITS |
|
compression = LZW |
|
depth = 1 | TYPE = JPEG |
resolution = 1200 | Not supported; results will vary. Some printers will default to a scan resolution of 150 dpi if this value is used. |