Environmental conditions

Note: When shipping or storing printers, always pack the printer supplies (such as cartridges and photoconductors) separately.
Environmental specifications for CS310, CS410, CS510, CX310, CX410, and CX510

Environment

Specifications

Air relative humidity

8 to 80%

Air temperature

Product operating

60 to 90.0°F (15.6 to 32.20°C)

Product power off

50 to 104.0°F (10.0 to 40.0°C)

Wet bulb temperature

Product operating

73.0°F (22.80°C) Maximum

Product power off

80.10°F (26.70°C) Maximum


Printer humidity values

Printer model

Air relative humidity (RH)

CS310, CS410, CS510, CX310, CX410, CX510 (unpackaged)

8–80%

CX310, CX410, CX510 (packaged)

5–95%


Shipping and storage specifications for CS310, CS410, CS510, CX310, CX410, and CX510

Shipping and storage

Specifications

Cartridge or imaging unit

Short term shipping

-40 to 110.0°F (-40 to 43.3°C)

Long term storage*

34 to 95.0°F (1.1 to 35°C)

8 to 80% RH

Printer with supplies (only for CS310, CS410, and CS510)

Short term shipping

-40 to 110.0°F (-40 to 43.3°C)

Long term storage

34 to 95.0°F (1.1 to 35°C)

8 to 80% RH

Printer with cartridges (only for CX310, CX410, and CX510)

104°F (-40 to 40°C)

Printer without cartridges

CS310, CS410, and CS510

-40 to 110.0°F (-40 to 43.3°C)

CX310, CX410, and CX510

104°F (-40 to 40°C)